OVERVIEW

SUNOCO SUNVIS 1000 HVI HYDRAULIC OILS are supreme quality anti-wear hydraulic oils specially developed for applications subjected to wide range of temperature or where small viscosity change with fluctuating temperature is needed. They are formulated with severely hydro-processed Group II base oils, a highly shear stable polymer and an advanced additive system to meet the stringent requirements of modern hydraulic systems using high pressure high output pumps and critical requirement of other hydraulic system. 

FEATURES & BENEFITS

SUNOCO SUNVIS 1000 HVI HYDRAULIC OILS have outstanding thermo-oxidative stability and their low & high temperature performance allows for extended service life. They provide excellent anti-wear property, rust & corrosion protection, water separation & air-release properties and hydrolytic stability to reduce breakdowns and help improve production capacity.  SUNOCO SUNVIS 1000 HYDRAULIC OILS have high dielectric strength for use in electrical service bucket trucks as an insulating oil.*

APPLICATIONS

SUNOCO SUNVIS 1000 HVI HYDRAULIC OILS are designed for hydraulic and power transmission systems subjected to a wide range of ambient & operating temperatures, requiring extended oil change intervals, and critical hydraulic systems. SUNOCO SUNVIS 1000 HVI HYDRAULIC OILS SERIES are employed in hydraulic systems of excavators, cranes and hydrostatic drives subjected to most severe outdoor operating conditions, and hydraulic systems operating under high pressures and requiring high degree of load carrying capability and anti-wear protection. These oils are recommended for use in outdoor mobile equipment that is used year-round such as cranes, bucket trucks (cherry pickers), cranes, aerial lifts, and the like.

SPECIFICATIONS

DIN 51524 Part 3 HVLP • AFNOR NFE 48-603 (HV) • ISO 11158 L-HV • Poclain • Hitachi • Cincinnati Lamb • Eaton • Vickers • Denison

 

*Dielectric strength measurement given at point of manufacture. Dielectric strength deteriorates rapidly with contamination from particulates and moisture; oil must be kept clean and dry at all times.

Product Code

4873

4813

4823

4833

4843

4863

Product

SUNVIS 1015

SUNVIS 1022

SUNVIS 1032

SUNVIS 1046

SUNVIS 1068

SUNVIS 1100

Viscosity, cSt @ 40 °C

15

22

32

46

68

100

Viscosity Index

152

151

144

145

148

135

Flash Point, °C

180

192

219

222

232

242

Pour Point, °C

-55

-45

-40

-40

-42

-42

Rust Test

Pass

Pass

Pass

Pass

Pass

Pass

Emulsion Test 30 mins. max @ 54 oC

Pass

Pass

Pass

Pass

Pass

-

Emulsion Test 30 mins. max @ 82 oC

-

-

-

-

-

Pass

Foam Test, foam after 10 minutes of settling for all sequences

Pass

Pass

Pass

Pass

Pass

Pass

Turbine Oil Stability Test, hrs.

5000+

5000+

5000+

5000+

5000+

4000+

FZG, Fail Load Stage, minimum

-

-

11

11

11

11

Density @ 15°C

0.855

0.857

0.861

0.855

0.858

0.861

Dielectric Strength, kV min*

35

35

35

35

35

35